MRCOOL Hyper Heat 2nd Gen 60K BTU, 5 Ton, 16 SEER2 Heat Pump Condenser and Ducted Air Handler with 35 Ft. R-454B No-Vac Lineset - CENTRAL-60-HP-230B35-Schneller Versand
SALE!

MRCOOL Hyper Heat 2nd Gen 60K BTU, 5 Ton, 16 SEER2 Heat Pump Condenser and Ducted Air Handler with 35 Ft. R-454B No-Vac Lineset – CENTRAL-60-HP-230B35-Schneller Versand

Original price was: CHF2'866.00.Current price is: CHF298.98.

SKU: 8375539630271 Category:

Description

MRCOOL Hyper Heat 2nd Gen 60K BTU, 5 Ton, 16 SEER2 Heat Pump Condenser and Ducted Air Handler with 35 Ft. R-454B No-Vac Lineset – CENTRAL-60-HP-230B35

The MRCOOL Central Heat Pump & Air Conditioner Bundle is a heating and cooling system you need to stay warm in winter, cool in summer, and energy efficient all year long.

Features
  1. MRCOOL Hyper Heat 2nd Gen 60K BTU, 5 Ton, 16 SEER2 Central Ducted Condenser

  2. MRCOOL VersaPro 2nd Gen 54K BTU, 5 Ton Central Ducted Air Handler

  3. MRCOOL 25 Ft. R-454B No-Vac Lineset

  4. MRCOOL Smart Thermostat

1. MRCOOL Hyper Heat 2nd Gen 60K BTU, 5 Ton, 16 SEER2 Central Ducted Condenser (CENTRAL-60-HP-C-230B00-O)

  • Thermostat makes it easy to control your home’s climate.

  • 10-year warranty covering the compressor, parts, and labor,

2. MRCOOL VersaPro 2nd Gen 54K BTU, 5 Ton Central Ducted Air Handler (MVP-60-HP-MUAH-230A00-O)

  • Uses R-454B refrigerant
  • Provides flexible installation options
  • SEER2 rating of up to 16

3. MRCOOL 25 Ft. R-454B No-Vac Lineset (NV25-3834-O)

  • Kink Resistant – Precharged
  • Simple Secure Quick Connect

  • UV Protected Insulation

  • Works With: VersaPro 2nd Gen – Central Ducted Hyper Heat 2nd Gen

4. MRCOOL Smart Thermostat (MST04)

  • Ensure ideal temperature with presets for Home, Away, and Sleep that perfectly align to match your specific needs and preferences.

  • One App for All Your HVAC Systems

  • Global Control for Remote Accessibility

  • Works with Alexa, Google, Siri, and MRCOOL® Link

Specifications
Condenser
Dimensions 16.34″ D x 52.48″ H x 37.48″ W
SEER2 16
Tonnage 5
Cooling Capacity (BTU) 54000
Heating Capacity (BTU) 56000
Voltage (V) 208-230
Refrigerant Type R454B
Air Handler
Dimensions 24.49″ D x 52.99″ H x 21.02″ w
Tonnage 5
Cooling Capacity (BTU) 54000
Heating Capacity (BTU) 54000
Voltage (V) 115/208-230
Lineset
Dimensions 30″ D x 35″ H x 5″ W
Refrigerant Type R-454B
Refrigerant Volume (Oz) 2.11
Line Set Length 25ft
Lineset Fitting Type Quick-Connect
Liquid Line Size 3/8
Suction Line Size 3/4
What our Experts Think
  • High-Capacity Comfort – 60,000 BTU (5 Ton) system efficiently heats and cools large homes or light commercial spaces.

  • Energy-Efficient Operation – 16 SEER2 rating ensures lower utility costs while maintaining consistent comfort.

  • Heat Pump Technology – Provides reliable year-round heating and cooling.

  • 35 Ft. R-454B No-Vac Lineset – Pre-charged extended line set simplifies installation and reduces labor time.

  • Durable & Quiet – 2nd Gen design ensures long-lasting, low-noise performance for reliable operation.

Q&A

Q: What is included in this MRCOOL Hyper Heat 2nd Gen system?
A: It includes a 60,000 BTU (5 ton) heat pump condenser, ducted air handler, and a 35 ft. pre-charged R-454B No-Vac lineset for simplified installation.

Q: How energy efficient is the system?
A: With a 16 SEER2 rating, it provides efficient cooling and heating while reducing energy costs.

Q: Can it provide both heating and cooling?
A: Yes, the heat pump condenser delivers year-round comfort, handling both heating and cooling needs effectively.

Q: What makes the No-Vac lineset beneficial?
A: The pre-charged R-454B No-Vac lineset eliminates the need for vacuum pumps or additional refrigerant charging, simplifying installation.

Q: What size area can it cover?
A: Suitable for larger homes or commercial spaces up to approximately 2,500–3,000 sq. ft., depending on insulation and climate.

Q: Who should choose this system?
A: Homeowners or businesses seeking a high-capacity, energy-efficient central HVAC system with easy installation and reliable year-round performance.

Maintenance Tips
  • Air Filter Care: Replace or clean filters every 1–3 months for optimal airflow and efficiency.

  • Outdoor Unit Maintenance: Keep condenser free of leaves, dirt, and debris.

  • Ductwork Inspection: Seal leaks and clean ducts to ensure even air distribution.

  • Condensate Drain: Check and clear drain lines regularly to prevent water damage.

  • Coil Cleaning: Schedule annual cleaning of evaporator and condenser coils for peak performance.

  • Lineset Check: Inspect the 35 ft. R-454B No-Vac lineset for proper installation, insulation, and integrity.

  • Heat Kit Check: Verify electric heat kit operation if included, and inspect connections.

  • Professional Service: Schedule yearly maintenance to maintain 16 SEER2 efficiency and extend system life.

Reviews

There are no reviews yet.

Be the first to review “MRCOOL Hyper Heat 2nd Gen 60K BTU, 5 Ton, 16 SEER2 Heat Pump Condenser and Ducted Air Handler with 35 Ft. R-454B No-Vac Lineset – CENTRAL-60-HP-230B35-Schneller Versand”

Deine E-Mail-Adresse wird nicht veröffentlicht. Erforderliche Felder sind mit * markiert